Neocare

Paediatric Ventilator

It is an electronically controlled ventilator based on the widely accepted technique of continuous flow and pressure control modes. There is an option to select the inspiratory and expiratory flow separately. Both volume and pressure limiting features have been added to reduce the possibilities of Volume Trauma or Barotrauma. The sensing device at the proximal to the patient gives quick response and sensitive triggering. Both the pressure and the flow triggering are available. The use of closed feedback system has made the control of ventilation very accurate. The provision of independent CPAP mode and PSV makes the device very versatile.

Features

  • Large LCD display

Adopts Continuous Gas Flow technique

Ventilating newly born babies with continuous flow is a proven technique in view of safety and comfort. With its weak muscle power, the baby can easily breathe in from this continuous flow. Outward movement of flow drives away the exhaled CO2 during expiration.

Pressure Control mode (PCV)

Ventilating with untried tidal volume might have adverse consequences as infants and new-borns have delicate lungs. Controlling the pressure is thus considered safer in view of such consequences of barotrauma/volume-trauma. The modes of ventilation are so all made to pressure controlled.

Volume & Pressure Limiting

Considering the very delicate nature of lungs, it is essential to take additional safety measures. The ventilator so provides for limiting the pressure and volume to avoid adverse consequences. The limit of pressure and volume may be set suitably on the panel.

Both flow and pressure triggering

The breathing effort of the patient can be detected by fall in pressure or the flow of gas towards the patient. On detection of either these phenomena, the ventilator initiates the mechanical breath. The triggering is very effective as either of the two factors are considered, instead of only one.

To make the triggering more effective, the sensor has been placed at the proximal of the patient.

Automatic calibration of oxygen sensor

Calibration of oxygen cell is desired for monitoring FiO2 correctly as the cell gets affected with continuous exposer to oxygen. The ventilator thus perform the required calibration at the start of the operation. However, the operator has the option to skip.

Servo controlled FiO2

Blending of air and oxygen is done by precise regulation of the flow of gases with the help of advanced proportional valves. The controller does it depending on the closed feedback provided by the oxygen sensor. The closed feedback makes the blending accurate although outflow may vary widely.

Separate CPAP mode

In addition to continuous flow, the ventilator also uses a dynamic demand valve to meet the inspiratory demand of the patient. This enables to maintain the continuous positive airway pressure (CPAP) effectively.

As the CPAP keep lungs partially inflated, the PC level is set suitably for adequate mechanical ventilation.

Pressure Support Ventilation (PSV)

PSV is available as a combination mode with SIMV. It works by raising the circuit pressure instantly when the patient makes an effort. It makes the gradient for flow of gas into the lung and reduces the WOB. As the inspiratory demand tends to cease, the gradient is withdrawn. PSV is active between the mandatory breaths of SIMV.

Apnoea backup ventilation

When the patient is on support mode, it is supposed to breathe spontaneously. But at times, the patient may fail and the support mode becomes ineffective. To safeguard, it is desired to have a backup control mode to ventilate during the period. The ventilator provides the facility as Apnea Backup. The backup is withdrawn when the spontaneous breathing is restored suitably.

Monitoring of patient data

The patient data are monitored on real time basis.  The display shows the data in tabulation form at the Centre-bottom of the panel. The patient data clearly shows the limiting values for different parameters also.

Specifications

LCD Display
12.1 inches coloured TFT
Modes
AC, SIMV/IMV, CPAP with backup ventilation & Standby
PCV
0 to 40 cmH2O
Flow
2 to 25 LPM
Frequency
1 to 150 breaths per minute
Inspiratory time
0. 2 to 3. 0 seconds
Triggering
Flow triggering :1 to 10 LPM
Pressure Triggering : 0.5 to 8 cmH2O
Exp. pressure
0 to 20 cmH2O
Insp. Pressure limit
5 to 50 cmH2O
Tidal Volume
6 to 300 ml

I : E ratio
1:1 to 1:10 (AC ), 1:1 to 1:60 (SIMV); Inverse 1:1 to 4:1
Safety Pressure Relief
15 to 50 cmH2O
Alarm mute
30 seconds
Alarms
High/Low Insp. Pressure, High/Low Tidal Vol, High/Low FiO2, Gas Failure, Apnea
Patient Data
Frequency, PIP, MAP, Pplat, TV(exp), TV(insp), Spontaneous Exp Volume, MV,  FiO2 & I / E ratio
Ventilation curves
Pressure-Time and Flow-Time
Humidifier
Heated
Power source
220 VAC, 50 Hz
Battery backup
6 hours (control module)

Product Brochure
Product Enquiry

RELATED PRODUCTS

Medivent Gold

Medivent Gold

Carewel

Carewel

Babywell

Babywell

Medivent Excel

Medivent Excel

Quick Links

  • HOME
  • PRODUCTS
  • ABOUT US
  • QC
  • R&D
  • CONTACT US

Contact Us

Premier Medical Systems and Devices Pvt. Ltd.

A-113, Sector 63, Noida-201307, Uttar Pradesh, India

support@medisyscare.in

0120 4272733 / 0120 4272734

Enquiry

    All Copyright Reserved